Baxi UK Limited declare that no substances
harmful to health are contained in the
appliance or used during appliance
manufacture.
1.1 Description
1. The Baxi Combi 80Eco is a fully automatic gas
fired wall mounted combination boiler. It is room
sealed and fan assisted, and will serve central
heating and mains fed domestic hot water.
2. The boiler is set to give a maximum output of
24.0 kW.
3. It is designed for use on Natural Gas (G20) and
can be converted to use Propane or Butane.
4. The boiler is suitable for use only on fully pumped
sealed heating systems. Priority is given to
domestic hot water.
5. The boiler data badge gives details of the model,
serial number and Gas Council number and is
situated on the control box. It is visible when the
case front panel is removed (Fig. 1).
6. The boiler is intended to be installed in residential
/ commercial / light industrial E.M.C. environments
on a governed meter supply only.
7. The boiler must be installed with one of the
purpose designed flues such as the standard
horizontal flue kit, part no. 247719.
8. All systems must be thoroughly flushed and
treated with inhibitor (see section 6.2).
1.2 Installation
1. The appliance is suitable for installation only in G.B. and I.E.
and should be installed in accordance with the rules in force.
For Ireland install in accordance with I.S.813 “I
NSTALLATION OF
GAS APPLIANCES. The installation must be carried out by a
CORGI Registered Installer or other competent person and be
in accordance with the relevant requirements of G
AS SAFETY
(Installation and Use) REGULATIONS, the BUILDING REGULATIONS
(Scotland) (Consolidation), the LOCAL BUILDING REGULATIONS,
the C
URRENT I.E.E. WIRING REGULATIONS and the bye laws of the
Local Water Undertaking. Where no specific instructions are
given, reference should be made to the relevant BRITISH
STANDARD CODES OF PRACTICE.
1.3 Optional Extras
Various flue extensions, bends, vertical flue kits,
control accessories etc. are available as optional
extras. These are detailed in a separate publication.
1.0 Introduction
4
Data Badge
Fig. 1
Control Box
Case Front Panel
Benchmark Log Book
As part of the industry-wide Benchmark initiative all Baxi boilers now
include an Installation, Commissioning and Service Record Log Book.
Please read the Log Book carefully and complete all sections relevant to
the appliance and installation. These include sections on the type of
controls employed, flushing the system, burner operating pressure etc.
The details of the Log Book will be required in the event of any warranty
work. Also, there is a section to be completed at each subsequent regular
service visit. The Log Book must be left with the user.
NOTE: This appliance must be installed in
accordance with the manufacturers instructions
and the regulations in force. Read the instructions
fully before installing or using the appliance.