Seitenansicht 15
16
7.0 Site Requirements
7.12 Flue Options
1. The Baxi Combi 80Eco can be fitted with flue
systems as illustrated.
2. The standard flue is suitable only for horizontal
applications.
3. Maximum permissible equivalent flue lengths
are:-
Horizontal 5 metres
Vertical 4 metres
Vertical (Twin Pipe) 15 metres
4. Any additional in line bends in the flue system
must be taken into consideration.
Their equivalent lengths are:-
Concentric Pipes:
45° bend 0.5 metres
90° bend 1.0 metres
Twin Flue Pipe
45° bend 0.25 metres
90° bend 0.50 metres
The elbow supplied with the standard horizontal
flue is not included in any equivalent length
calculations
5. The illustrations opposite show examples of
maximum equivalent lengths.
6. Full details of part numbers and descriptions of
all optional flue components and kits can be
found in the Baxi Gas Central Heating Boilers
Installers Guide.
7. Instructions for guidance and fitting are
included in each kit where appropriate.
Horizontal
Flues
Vertical
Flues
Vertical
Flues
(Twin Pipe)
Maximum Length = 4m inc. 2 x 45° bends
Maximum Length = 14m
inc. 4 x 45° bends
Maximum Length = 2m
inc. 2 x 90° bends
Seitenansicht 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 43 44