Seitenansicht 38
10.0Changing Components
39
10.7 Changing Components (Cont)
1. To change Fan - Pressure Switch - Burner -
Burner Injector - Pilot Burner Injector - Gas
Manifold, proceed as follows:-
2. Release the four latches holding the combustion
box door (Fig. 108). Remove the combustion box
door by pulling forward from the bottom and
unhooking its top edge (Fig. 110).
3. Release the 5-pin electrical plug connecting the
pressure switch and fan (Fig. 109). Withdraw the
fan assembly by pulling forwards from the top
edge (Fig. 110).
10.8 Fan (Fig. 111)
IMPORTANT - 80 PF Models Only. On
appliances up to serial n
o
8999 use replacement
fan Baxi Part N
o
229422 G.C.N
o
364 979.
From serial n
o
9000 use replacement fan Baxi
Part N
o
237578 G.C.No 170 615.
1. Disconnect sensing probe from the pressure
switch at rubber tube connector.
2. Disconnect the 2 fan wires from the connection
on the electrical plug. Unscrew bracket securing
sensing probe into top of fan and remove the
sensing probe. Remove the 3 screws securing the
fan to the fan hood.
3. Remove the two screws securing the fan outlet
flange to the fan and remove. Clean all sealing
mastic from the outlet flange.
4. Fit the outlet flange onto the new fan, fix with
the 2 screws and seal the outside gap between the
fan body and the outlet fan with the mastic
provided.
5. Fit the new fan and re-assemble all components
in reverse order of dismantling, reconnect the new
fan wires into the connections on the electrical
plug - either wire can be connected into either
connection.
10.9 Pressure Switch (Fig. 112)
1. Disconnect sensing tube.
2. Remove the screw securing the pressure switch
to its bracket and unhook the pressure switch.
3. Disconnect the 3 electrical terminals from the
pressure switch. Note the position of the tags
before removal and reconnect in correct order.
4. Fit new pressure switch and re-assemble all
components in reverse order of dismantling
ensuring that the electrical terminals are
connected to their correspondingly marked tags.
Grey
Black
White
Fig. 108
Fig. 109
Fig. 110
Fig. 111
Fig. 112
Outlet Flange
Sensing Tube
Sensing Tube
Fan
Seitenansicht 38